W DOC AIRBUS | TSM A320F

Display System Version Inconsistency of the lower ECAM DU


TASK 31-63-81-810-941-A
Display System Version Inconsistency of the lower ECAM DU


1. Possible Causes
  • DU-ECAM, LOWER [4WT2]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 31-60-00-610-001
X LOADING Procedure of the DMC1 to the PFD CAPT, ND CAPT, the EWD or the SD
AMM 31-60-00-740-004
EIS System Test
AMM 31-60-00-740-011
LRU Identification Check
AMM 31-63-22-000-001
Removal of the Display Unit
AMM 31-63-22-400-001
Installation of the Display Unit
3. Fault Confirmation
Subtask 31-63-81-860-081-A ** ON A/C NOT FOR ALL
A. Reset the DU
   (1) On the ECAM Control Panel (6WT):
  • turn the ECAM lower display potentiometer to the OFF position then to the BRT middle position. If the DISPLAY SYSTEM VERSION INCONSISTENCY message is not shown on the lower ECAM DU
  • no maintenance action is necessary.
     (a) If the DISPLAY SYSTEM VERSION INCONSISTENCY message is shown on the lower ECAM DU
  • do the following test.
Subtask 31-63-81-740-324-A ** ON A/C NOT FOR ALL
B. Test
4. Fault Isolation
Subtask 31-63-81-810-222-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message INVALID LRU IDENT:
   (1) Make sure that the EIS software P/N of the lower ECAM DU is the same as the EIS software P/N on the microdisk that is in the storage box.
     (a) If the part numbers are the same:
     (b) If the part numbers are not the same:
Subtask 31-63-81-740-325-A ** ON A/C NOT FOR ALL
B. Do the test given in Para. 3.A