Display System Version Inconsistency of the upper ECAM DU
TASK 31-63-81-810-940-A
Display System Version Inconsistency of the upper ECAM DU
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 31-63-81-860-080-A ** ON A/C NOT FOR ALL
Subtask 31-63-81-810-221-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:31:07 UTC
Display System Version Inconsistency of the upper ECAM DU
1. Possible Causes
- DU-ECAM, UPPER [4WT1]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 31-60-00-610-001 | X LOADING Procedure of the DMC1 to the PFD CAPT, ND CAPT, the EWD or the SD |
| AMM 31-60-00-740-004 | EIS System Test |
| AMM 31-60-00-740-011 | LRU Identification Check |
| AMM 31-63-22-000-001 | Removal of the Display Unit |
| AMM 31-63-22-400-001 | Installation of the Display Unit |
Subtask 31-63-81-860-080-A ** ON A/C NOT FOR ALL
A. Reset the DU
(1) On the ECAM Control Panel (6WT):
Subtask 31-63-81-740-322-A ** ON A/C NOT FOR ALL 4. Fault Isolation(1) On the ECAM Control Panel (6WT):
- turn the ECAM upper display potentiometer to the OFF position then to the BRT middle position. If the DISPLAY SYSTEM VERSION INCONSISTENCY message is not shown on the upper ECAM DU
- no maintenance action is necessary.
- do the following test.
Subtask 31-63-81-810-221-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message INVALID LRU IDENT:
(a) If the part numbers are the same:
Subtask 31-63-81-740-323-A ** ON A/C NOT FOR ALL - Do the LRU Identification Check AMM 31-60-00-740-011
(a) If the part numbers are the same:
- replace the DU-ECAM, UPPER [4WT1] AMM 31-63-22-000-001 AMM 31-63-22-400-001
- do the crossloading of the DMC1 to the upper ECAM DU AMM 31-60-00-610-001
B. Do the test given in Para. 3.A