1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 31-63-81-860-078-A ** ON A/C NOT FOR ALL
Subtask 31-63-81-810-219-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:31:06 UTC
Display System Version Inconsistency of the F/O PFD DU
1. Possible Causes
- PFD-F/O [2WT2]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 31-60-00-610-002 | X LOADING Procedure of the DMC2 to the PFD F/O or the ND F/O |
| AMM 31-60-00-740-004 | EIS System Test |
| AMM 31-60-00-740-011 | LRU Identification Check |
| AMM 31-63-22-000-001 | Removal of the Display Unit |
| AMM 31-63-22-400-001 | Installation of the Display Unit |
Subtask 31-63-81-860-078-A ** ON A/C NOT FOR ALL
A. Reset the DU
(1) On the F/O LIGHTING/LOUD SPEAKER control panel (500VU):
Subtask 31-63-81-740-318-A ** ON A/C NOT FOR ALL 4. Fault Isolation(1) On the F/O LIGHTING/LOUD SPEAKER control panel (500VU):
- turn the PFD potentiometer to the OFF position then to the BRT middle position. If the DISPLAY SYSTEM VERSION INCONSISTENCY message is not shown on the F/O PFD DU
- no maintenance action is necessary.
- do the following test.
Subtask 31-63-81-810-219-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message INVALID LRU IDENT:
(a) If the part numbers are the same:
Subtask 31-63-81-740-319-A ** ON A/C NOT FOR ALL - Do the LRU Identification Check AMM 31-60-00-740-011
(a) If the part numbers are the same:
- replace the PFD-F/O [2WT2] AMM 31-63-22-000-001 AMM 31-63-22-400-001
- do the crossloading of the DMC2 to the F/O PFD DU AMM 31-60-00-610-002
B. Do the test given in Para. 3.A