W DOC AIRBUS | TSM A320F

Display System Version Inconsistency of the CAPT ND DU


TASK 31-63-81-810-937-A
Display System Version Inconsistency of the CAPT ND DU


1. Possible Causes
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 31-60-00-610-001
X LOADING Procedure of the DMC1 to the PFD CAPT, ND CAPT, the EWD or the SD
AMM 31-60-00-740-004
EIS System Test
AMM 31-60-00-740-011
LRU Identification Check
AMM 31-63-22-000-001
Removal of the Display Unit
AMM 31-63-22-400-001
Installation of the Display Unit
3. Fault Confirmation
Subtask 31-63-81-860-077-A ** ON A/C NOT FOR ALL
A. Reset the DU
   (1) On the CAPT LIGHTING/LOUD SPEAKER control panel (301VU):
  • turn the ND potentiometer to the OFF position then to the BRT middle position. If the DISPLAY SYSTEM VERSION INCONSISTENCY message is not shown on the CAPT ND DU
  • no maintenance action is necessary.
     (a) If the DISPLAY SYSTEM VERSION INCONSISTENCY message is shown on the CAPT ND DU
  • do the following test.
Subtask 31-63-81-740-316-A ** ON A/C NOT FOR ALL
B. Test
4. Fault Isolation
Subtask 31-63-81-810-218-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message INVALID LRU IDENT:
   (1) Make sure that the EIS software P/N of the CAPT ND DU is the same as the EIS software P/N on the microdisk that is in the storage box.
     (a) If the part numbers are the same:
     (b) If the part numbers are not the same:
Subtask 31-63-81-740-317-A ** ON A/C NOT FOR ALL
B. Do the test given in Para. 3.A
[Rev.8 from Aug 2018] 2026.04.04 04:31:06 UTC