W DOC AIRBUS | TSM A320F

Power Supply Interruption Detected by the DMC


TASK 31-63-81-810-909-A
Power Supply Interruption Detected by the DMC


1. Possible Causes

2. Fault Confirmation
Subtask 31-63-81-869-050-A ** ON A/C NOT FOR ALL
A. Not Applicable: this message is intermittent.
NOTE: A computer gives a POWER SUPPLY INTERRUPT message if the electrical power stops for more than 200ms and then starts again.
3. Fault Isolation
Subtask 31-63-81-810-177-A ** ON A/C NOT FOR ALL
A. If the POST FLIGHT REPORT gives the maintenance message POWER SUPPLY INTERRUPT:
  • no maintenance action is necessary.
Subtask 31-63-81-810-178-A ** ON A/C NOT FOR ALL
B. If there is an additional message related to the Aircraft Electrical Power System:
  • do the related trouble shooting procedure(s).
[Rev.8 from Aug 2018] 2026.04.04 04:31:04 UTC