1. Possible Causes
  • LGCIU-2 [5GA2]
  • wiring
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 31-60-00-740-004
EIS System Test
ASM 316200
AMM 32-31-71-000-001
Removal of the LGCIU
AMM 32-31-71-400-001
Installation of the LGCIU
3. Fault Confirmation
Subtask 31-63-81-740-258-A ** ON A/C NOT FOR ALL
A. Test
Do the EIS system test AMM 31-60-00-740-004.
4. Fault Isolation
Subtask 31-63-81-810-174-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance messages LGCIU2 FLIGHT DISCRETE (5GA2)/ DMC1(1WT1) and LGCIU2 FLIGHT DISCRETE (5GA2)/DMC2(1WT2) and LGCIU2 FLIGHT DISCRETE (5GA2)/DMC3(1WT3):
   (1) if the fault continues:
  • check the wiring from LGCIU2(5GA2) pins AA/13K, 15K and pins AA/13J, 15J to the first terminal block ASM 316200
Subtask 31-63-81-740-259-A ** ON A/C NOT FOR ALL
B. Do the test given in Para. 3.A.