Loss of the LGCIU 2 Discrete on the DMC's
TASK 31-63-81-810-906-A
Loss of the LGCIU 2 Discrete on the DMC's
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 31-63-81-740-258-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 31-63-81-810-174-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:31:03 UTC
Loss of the LGCIU 2 Discrete on the DMC's
1. Possible Causes
- LGCIU-2 [5GA2]
- wiring
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 31-60-00-740-004 | EIS System Test |
| ASM 316200 | |
| AMM 32-31-71-000-001 | Removal of the LGCIU |
| AMM 32-31-71-400-001 | Installation of the LGCIU |
Subtask 31-63-81-740-258-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 31-63-81-810-174-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance messages LGCIU2 FLIGHT DISCRETE (5GA2)/ DMC1(1WT1) and LGCIU2 FLIGHT DISCRETE (5GA2)/DMC2(1WT2) and LGCIU2 FLIGHT DISCRETE (5GA2)/DMC3(1WT3):
Subtask 31-63-81-740-259-A ** ON A/C NOT FOR ALL - replace the LGCIU-2 [5GA2] AMM 32-31-71-000-001 and AMM 32-31-71-400-001
- check the wiring from LGCIU2(5GA2) pins AA/13K, 15K and pins AA/13J, 15J to the first terminal block ASM 316200
B. Do the test given in Para. 3.A.