Failure of the Pin Programming of the Lower ECAM DU by the DMC1
TASK 31-63-81-810-880-A
Failure of the Pin Programming of the Lower ECAM DU by the DMC1
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 31-63-81-740-206-A ** ON A/C NOT FOR ALL Subtask 31-63-81-740-206-B ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 31-63-81-810-136-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:31:01 UTC
Failure of the Pin Programming of the Lower ECAM DU by the DMC1
1. Possible Causes
- DU-ECAM, LOWER [4WT2]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 31-60-00-740-002 | Perform Electronic Instrument System (EIS) Input Test |
| AMM 31-60-00-740-004 | EIS System Test |
| AMM 31-63-22-000-001 | Removal of the Display Unit |
| AMM 31-63-22-400-001 | Installation of the Display Unit |
| AWM 316806 |
Subtask 31-63-81-740-206-A ** ON A/C NOT FOR ALL Subtask 31-63-81-740-206-B ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 31-63-81-810-136-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message DMC1 : DU ECAM2 POS PIN:
Subtask 31-63-81-740-207-A ** ON A/C NOT FOR ALL - do a check for ground signals at lower ECAM DU (4WT2) connector AA AWM 316806.
- repair the wiring.
- replace the DU-ECAM, LOWER [4WT2] AMM 31-63-22-000-001 and AMM 31-63-22-400-001.
B. Do the test given in Para. 3.
Subtask 31-63-81-810-136-B ** ON A/C NOT FOR ALL C. If the test gives the maintenance message WRG: PIN PROG/DU SD(4WT2)
Subtask 31-63-81-740-207-B ** ON A/C NOT FOR ALL - do a check for ground signals at lower ECAM DU (4WT2) connector AA AWM 316806.
- repair the wiring.
- replace the DU-ECAM, LOWER [4WT2] AMM 31-63-22-000-001 and AMM 31-63-22-400-001.