Loss of the Lower ECAM DU by the DMC1
TASK 31-63-81-810-879-A
Loss of the Lower ECAM DU by the DMC1
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 31-63-81-740-204-A ** ON A/C NOT FOR ALL Subtask 31-63-81-740-204-B ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 31-63-81-810-135-A
[Rev.8 from Aug 2018]
2026.04.04 04:31:01 UTC
Loss of the Lower ECAM DU by the DMC1
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 31-60-00-720-002 | Operational Test of the DMC/DU data bus |
| AMM 31-60-00-740-002 | Perform Electronic Instrument System (EIS) Input Test |
| ASM 316104 | |
| AMM 31-63-22-000-001 | Removal of the Display Unit |
| AMM 31-63-22-400-001 | Installation of the Display Unit |
| AMM 31-63-34-000-001 | Removal of the DMC |
| AMM 31-63-34-400-001 | Installation of the DMC |
Subtask 31-63-81-740-204-A ** ON A/C NOT FOR ALL Subtask 31-63-81-740-204-B ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 31-63-81-810-135-A
A. If the test gives the maintenance message DMC1 - DU ECAM2 LINK:
Subtask 31-63-81-740-205-A - replace the DU-ECAM, LOWER [4WT2] AMM 31-63-22-000-001 and AMM 31-63-22-400-001.
- do a check of the
wiring from the lower ECAM DU (4WT2) to the DMC1 (1WT1) > ASM 316104.
- repair the wiring.
- replace the DMC-1 [1WT1] AMM 31-63-34-000-001 and AMM 31-63-34-400-001.
B. Do the test given in Para. 3.