W DOC AIRBUS | TSM A320F

Loss of the Upper ECAM DU by the DMC2


TASK 31-63-81-810-878-A
Loss of the Upper ECAM DU by the DMC2


1. Possible Causes
  • DU-ECAM, UPPER [4WT1]
  • wiring from the upper ECAM DU (4WT1) to the DMC2 (1WT2)
  • DMC-2 [1WT2]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 31-60-00-740-002
Perform Electronic Instrument System (EIS) Input Test
AMM 31-60-00-740-004
EIS System Test
ASM 316104
AMM 31-63-22-000-001
Removal of the Display Unit
AMM 31-63-22-400-001
Installation of the Display Unit
AMM 31-63-34-000-001
Removal of the DMC
AMM 31-63-34-400-001
Installation of the DMC
3. Fault Confirmation
Subtask 31-63-81-740-202-A ** ON A/C NOT FOR ALL
A. Test
Do the EIS input test AMM 31-60-00-740-002.
Subtask 31-63-81-740-202-B ** ON A/C NOT FOR ALL
A. Test
Do the EIS system test AMM 31-60-00-740-004.
4. Fault Isolation
Subtask 31-63-81-810-134-A
A. If the test gives the maintenance message DMC2 - DU ECAM1 LINK:
   (1) If the fault continues:
  • do a check of the wiring from the upper ECAM DU (4WT1) to the DMC2 (1WT2)> ASM 316104.
     (a) If there is no continuity:
  • repair the wiring.
     (b) If there is continuity:
Subtask 31-63-81-740-203-A
B. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:31:00 UTC