Failure of the F/O PFD
TASK 31-63-81-810-875-A
Failure of the F/O PFD
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 31-63-81-740-198-A ** ON A/C NOT FOR ALL Subtask 31-63-81-740-198-B ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 31-63-81-810-132-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:31:00 UTC
Failure of the F/O PFD
1. Possible Causes
- PFD-F/O [2WT2]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 31-60-00-740-002 | Perform Electronic Instrument System (EIS) Input Test |
| AMM 31-60-00-740-004 | EIS System Test |
| AMM 31-63-22-000-001 | Removal of the Display Unit |
| AMM 31-63-22-400-001 | Installation of the Display Unit |
Subtask 31-63-81-740-198-A ** ON A/C NOT FOR ALL Subtask 31-63-81-740-198-B ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 31-63-81-810-132-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message DU PFD2:
Subtask 31-63-81-810-132-B ** ON A/C NOT FOR ALL - replace the PFD-F/O [2WT2] AMM 31-63-22-000-001 and AMM 31-63-22-400-001.
A. If the test gives the maintenance message DU PFD FO(2WT2)
Subtask 31-63-81-740-199-A - replace the PFD-F/O [2WT2] AMM 31-63-22-000-001 and AMM 31-63-22-400-001.
B. Do the test given in Para. 3.