Failure of the CAPT PFD
TASK 31-63-81-810-874-A
Failure of the CAPT PFD
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 31-63-81-740-196-A ** ON A/C NOT FOR ALL Subtask 31-63-81-740-196-B ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 31-63-81-810-131-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:31:00 UTC
Failure of the CAPT PFD
1. Possible Causes
- PFD-CAPT [2WT1]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 31-60-00-740-002 | Perform Electronic Instrument System (EIS) Input Test |
| AMM 31-60-00-740-004 | EIS System Test |
| AMM 31-63-22-000-001 | Removal of the Display Unit |
| AMM 31-63-22-400-001 | Installation of the Display Unit |
Subtask 31-63-81-740-196-A ** ON A/C NOT FOR ALL Subtask 31-63-81-740-196-B ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 31-63-81-810-131-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message:
DU PFD1
Subtask 31-63-81-810-131-B ** ON A/C NOT FOR ALL DU PFD1
- replace the PFD-CAPT [2WT1] AMM 31-63-22-000-001 and AMM 31-63-22-400-001.
A. If the test gives the maintenance message:
DU PFD CAPT(2WT1)
Subtask 31-63-81-740-197-A DU PFD CAPT(2WT1)
- replace the PFD-CAPT [2WT1] AMM 31-63-22-000-001 and AMM 31-63-22-400-001.