W DOC AIRBUS | TSM A320F

Failure of the Lower ECAM DU Pin Programming Detected by the DMC2


TASK 31-63-81-810-855-A
Failure of the Lower ECAM DU Pin Programming Detected by the DMC2


1. Possible Causes
  • ground signals at lower ECAM DU (4WT2) connector AA
  • DU-ECAM, LOWER [4WT2]
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 31-60-00-740-002
Perform Electronic Instrument System (EIS) Input Test
AMM 31-60-00-740-004
EIS System Test
AMM 31-63-22-000-001
Removal of the Display Unit
AMM 31-63-22-400-001
Installation of the Display Unit
AWM 316806
3. Fault Confirmation
Subtask 31-63-81-740-158-A ** ON A/C NOT FOR ALL
A. Test
Do the EIS input test AMM 31-60-00-740-002.
Subtask 31-63-81-740-158-B ** ON A/C NOT FOR ALL
A. Test
Do the EIS system test AMM 31-60-00-740-004.
4. Fault Isolation
Subtask 31-63-81-810-112-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message:
DMC2: DU ECAM2 POS PIN
  • do a check for ground signals at lower ECAM DU (4WT2) connector AA AWM 316806.
   (1) If the wiring is not correct:
  • repair the wiring.
   (2) If the wiring is correct:
Subtask 31-63-81-740-159-A ** ON A/C NOT FOR ALL
B. Do the test given in Para. 3.
Subtask 31-63-81-810-112-B ** ON A/C NOT FOR ALL
C. If the test gives the maintenance message WRG: PIN PROG/DU SD(4WT2)
  • do a check for ground signals at lower ECAM DU (4WT2) connector AA AWM 316806.
   (1) If the wiring is not correct:
  • repair the wiring.
   (2) If the wiring is correct:
Subtask 31-63-81-740-159-B ** ON A/C NOT FOR ALL
D. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:30:59 UTC