Failure of the Lower ECAM DU Pin Programming Detected by the DMC2
TASK 31-63-81-810-855-A
Failure of the Lower ECAM DU Pin Programming Detected by the DMC2
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 31-63-81-740-158-A ** ON A/C NOT FOR ALL Subtask 31-63-81-740-158-B ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 31-63-81-810-112-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:30:59 UTC
Failure of the Lower ECAM DU Pin Programming Detected by the DMC2
1. Possible Causes
ground signals at lower ECAM DU (4WT2) connector AA - DU-ECAM, LOWER [4WT2]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 31-60-00-740-002 | Perform Electronic Instrument System (EIS) Input Test |
| AMM 31-60-00-740-004 | EIS System Test |
| AMM 31-63-22-000-001 | Removal of the Display Unit |
| AMM 31-63-22-400-001 | Installation of the Display Unit |
| AWM 316806 |
Subtask 31-63-81-740-158-A ** ON A/C NOT FOR ALL Subtask 31-63-81-740-158-B ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 31-63-81-810-112-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message:
DMC2: DU ECAM2 POS PIN
Subtask 31-63-81-740-159-A ** ON A/C NOT FOR ALL DMC2: DU ECAM2 POS PIN
- do a check for
ground signals at lower ECAM DU (4WT2) connector AA AWM 316806.
- repair the wiring.
- replace the DU-ECAM, LOWER [4WT2] AMM 31-63-22-000-001 and AMM 31-63-22-400-001.
B. Do the test given in Para. 3.
Subtask 31-63-81-810-112-B ** ON A/C NOT FOR ALL C. If the test gives the maintenance message WRG: PIN PROG/DU SD(4WT2)
Subtask 31-63-81-740-159-B ** ON A/C NOT FOR ALL - do a check for
ground signals at lower ECAM DU (4WT2) connector AA AWM 316806.
- repair the wiring.
- replace the DU-ECAM, LOWER [4WT2] AMM 31-63-22-000-001 and AMM 31-63-22-400-001.
D. Do the test given in Para. 3.