Loss of the Altitude Information on One PFD Detected by the DMC3
TASK 31-63-81-810-832-A
Loss of the Altitude Information on One PFD Detected by the DMC3
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 31-63-81-740-112-A ** ON A/C NOT FOR ALL Subtask 31-63-81-740-112-B ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 31-63-81-810-087-A
[Rev.8 from Aug 2018]
2026.04.04 04:30:56 UTC
Loss of the Altitude Information on One PFD Detected by the DMC3
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 31-60-00-740-002 | Perform Electronic Instrument System (EIS) Input Test |
| AMM 31-60-00-740-004 | EIS System Test |
| ASM 316104 | |
| AMM 31-63-22-000-001 | Removal of the Display Unit |
| AMM 31-63-22-400-001 | Installation of the Display Unit |
| AMM 31-63-34-000-001 | Removal of the DMC |
| AMM 31-63-34-400-001 | Installation of the DMC |
Subtask 31-63-81-740-112-A ** ON A/C NOT FOR ALL Subtask 31-63-81-740-112-B ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 31-63-81-810-087-A
A. If the EIS DMC selector switch (18WT) on the panel 8VU is at CAPT/3 and the test gives the maintenance message DMC3 : ALT DSPLY ERR MSG:
Subtask 31-63-81-810-088-A - on the panel 301VU, push the CAPT PFD/ND XFR pushbutton switch (9WT1)
- do the test given in Para. 3.
- replace the DMC-3 [1WT3] AMM 31-63-34-000-001 and AMM 31-63-34-400-001.
- do a check of the wiring from the DMC3 (1WT3) to the DMC1 (1WT1):
. pins AB/9B, 9C to pins AB/10J, 10H
. pins AB/9D, 9E to pins AB/10F, 10G ASM 316104.
- repair the wiring.
- do a check of the wiring from DMC1 (1WT1) pins AB/10B, 10C to the first terminal block ASM 316104.
- repair the wiring.
- do a check and repair the wiring from DMC1 (1WT1) pins AB/10D, 10E to the first terminal block ASM 316104.
- replace the PFD-CAPT [2WT1] AMM 31-63-22-000-001 and AMM 31-63-22-400-001.
- do a check of the wiring from CAPT PFD (2WT1) pins AA/21, 22 to the first terminal block ASM 316104.
- repair the wiring.
- do a check and repair the wiring from CAPT PFD (2WT1) pins AA/23, 24 to the first terminal block ASM 316104.
B. If the EIS DMC selector switch (18WT) on the panel 8VU is at F/O/3 and the test gives the maintenance message DMC3 : ALT DSPLY ERR MSG:
Subtask 31-63-81-740-113-A - on the panel 500VU, push the F/O PFD/ND XFR pushbutton switch (9WT2)
- do the test given in Para. 3.
- replace the DMC-3 [1WT3] AMM 31-63-34-000-001 and AMM 31-63-34-400-001.
- do a check of the wiring from the DMC3 (1WT3) to the DMC2 (1WT2):
. pins AB/9B, 9C to pins AB/10J, 10H
. pins AB/9D, 9E to pins AB/10F, 10G ASM 316104.
- repair the wiring.
- do a check of the wiring from DMC2 (1WT2) pins AB/10B, 10C to the first terminal block ASM 316104.
- repair the wiring.
- do a check and repair the wiring from DMC2 (1WT2) pins AB/10D, 10E to the first terminal block ASM 316104.
- replace the PFD-F/O [2WT2] AMM 31-63-22-000-001 and AMM 31-63-22-400-001.
- do a check of the wiring from F/O PFD (2WT2) pins AA/21, 22 to the first terminal block ASM 316104.
- repair the wiring.
- do a check and repair the wiring from F/O PFD (2WT2) pins AA/23, 24 to the first terminal block ASM 316104.
C. Do the test given in Para. 3.