Loss of the Attitude Information on the CAPT PFD Detected by the DMC1
TASK 31-63-81-810-823-A
Loss of the Attitude Information on the CAPT PFD Detected by the DMC1
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 31-63-81-740-094-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 31-63-81-810-077-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:30:55 UTC
Loss of the Attitude Information on the CAPT PFD Detected by the DMC1
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 31-60-00-740-002 | Perform Electronic Instrument System (EIS) Input Test |
| ASM 316104 | |
| AMM 31-63-22-000-001 | Removal of the Display Unit |
| AMM 31-63-22-400-001 | Installation of the Display Unit |
| AMM 31-63-34-000-001 | Removal of the DMC |
| AMM 31-63-34-400-001 | Installation of the DMC |
Subtask 31-63-81-740-094-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 31-63-81-810-077-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message DMC1 : ATT DSPLY ERR:
Subtask 31-63-81-740-095-A ** ON A/C NOT FOR ALL - on the panel 301VU, push the CAPT PFD/ND XFR pushbutton switch (9WT1) to get the PFD image on the CAPT ND
- do the test given in Para. 3.
- replace the DMC-1 [1WT1] AMM 31-63-34-000-001 and AMM 31-63-34-400-001.
- do a check of the wiring from DMC1 (1WT1) pins AB/9B, 9C to the first terminal block ASM 316104.
- repair the wiring.
- do a check and repair the wiring from DMC1 (1WT1) pins AB/9D, 9E to the first terminal block ASM 316104.
- replace the PFD-CAPT [2WT1] AMM 31-63-22-000-001 and AMM 31-63-22-400-001.
- do a check of the wiring from CAPT PFD (2WT1) pins AA/35, 36 to the first terminal block ASM 316104.
- repair the wiring.
- do a check and repair the wiring from CAPT PFD (2WT1) pins AA/38, 39 to the first terminal block ASM 316104.
B. Do the test given in Para. 3.