Loss of the ENG2 N1 Indication on the Upper ECAM DU Detected by the DMC1
TASK 31-63-81-810-813-A
Loss of the ENG2 N1 Indication on the Upper ECAM DU Detected by the DMC1
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 31-63-81-740-074-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 31-63-81-810-065-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:30:54 UTC
Loss of the ENG2 N1 Indication on the Upper ECAM DU Detected by the DMC1
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 31-60-00-740-002 | Perform Electronic Instrument System (EIS) Input Test |
| ASM 316104 | |
| AMM 31-63-22-000-001 | Removal of the Display Unit |
| AMM 31-63-22-400-001 | Installation of the Display Unit |
| AMM 31-63-34-000-001 | Removal of the DMC |
| AMM 31-63-34-400-001 | Installation of the DMC |
Subtask 31-63-81-740-074-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 31-63-81-810-065-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message:
DMC1: ENG2 N1 DSPLY ERR
DMC1: ENG2 N1 DSPLY ERR
Subtask 31-63-81-740-075-A ** ON A/C NOT FOR ALL DMC1: ENG2 N1 DSPLY ERR
- on the ECAM control panel, set the UPPER DISPLAY potentiometer to OFF and do the test given in Para. 3.
DMC1: ENG2 N1 DSPLY ERR
- replace the DMC-1 [1WT1] AMM 31-63-34-000-001 and AMM 31-63-34-400-001.
- do a check of the wiring from DMC1 (1WT1) pins AB/11B, 11C to the first terminal block ASM 316104.
- repair the wiring.
- do a check and repair the wiring from DMC1 (1WT1) pins AB/11D, 11E to the first terminal block ASM 316104.
- replace the DU-ECAM, UPPER [4WT1] AMM 31-63-22-000-001 and AMM 31-63-22-400-001.
- do a check of the wiring from upper ECAM DU (4WT1) pins AA/35, 36 to the first terminal block ASM 316104.
- repair the wiring.
- do a check and repair the wiring from upper ECAM DU (4WT1) pins AA/38, 39 to the first terminal block ASM 316104.
B. Do the test given in Para. 3.