Loss of F/O PFD or F/O ND or Lower ECAM DU Image
TASK 31-63-81-810-802-A
Loss of F/O PFD or F/O ND or Lower ECAM DU Image
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 31-63-81-740-052-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 31-63-81-810-051-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:30:53 UTC
Loss of F/O PFD or F/O ND or Lower ECAM DU Image
1. Possible Causes
- PFD-F/O [2WT2]
wiring from F/O PFD (2WT2) to DMC2 (1WT2) - DMC-2 [1WT2]
- ND-F/O [3WT2]
wiring from F/O ND (3WT2) to DMC2 (1WT2) - DU-ECAM, LOWER [4WT2]
wiring from lower ECAM DU (4WT2) to DMC2 (1WT2)
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 31-60-00-740-002 | Perform Electronic Instrument System (EIS) Input Test |
| ASM 316104 | |
| AMM 31-63-22-000-001 | Removal of the Display Unit |
| AMM 31-63-22-400-001 | Installation of the Display Unit |
| AMM 31-63-34-000-001 | Removal of the DMC |
| AMM 31-63-34-400-001 | Installation of the DMC |
Subtask 31-63-81-740-052-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 31-63-81-810-051-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message DMC2 : RECONF WIRING and there is no F/O PFD image:
Subtask 31-63-81-810-052-A ** ON A/C NOT FOR ALL - replace the PFD-F/O [2WT2] AMM 31-63-22-000-001 and AMM 31-63-22-400-001.
- do a check of the
wiring from F/O PFD (2WT2) to DMC2 (1WT2) from pins AA/35, 36 to pins AB/9B, 9C .
- repair the wiring.
- do a check and repair the
wiring from F/O PFD (2WT2) to DMC2 (1WT2) from pins AA/38, 39 to pins AB/9D, 9E ASM 316104.
- replace the DMC-2 [1WT2] AMM 31-63-34-000-001 and AMM 31-63-34-400-001.
B. If the test gives the maintenance message DMC2 : RECONF WIRING and there is no F/O ND image:
Subtask 31-63-81-810-053-A ** ON A/C NOT FOR ALL - replace the ND-F/O [3WT2] AMM 31-63-22-000-001 and AMM 31-63-22-400-001.
- do a check of the
wiring from F/O ND (3WT2) to DMC2 (1WT2) from pins AA/35, 36 to pins AB/10B, 10C .
- repair the wiring:
- do a check and repair the
wiring from F/O ND (3WT2) to DMC2 (1WT2) from pins AA/38, 39 to pins AB/10D, 10E ASM 316104.
- replace the DMC-2 [1WT2] AMM 31-63-34-000-001 and AMM 31-63-34-400-001.
C. If the test gives the maintenance message DMC1 : RECONF WIRING and there is no lower ECAM DU image:
Subtask 31-63-81-740-053-A ** ON A/C NOT FOR ALL - replace the DU-ECAM, LOWER [4WT2] AMM 31-63-22-000-001 and AMM 31-63-22-400-001.
- do a check of the
wiring from lower ECAM DU (4WT2) to DMC2 (1WT2) from pins AA/35, 36 to pins AB/11B, 11C .
- repair the wiring.
- do a check and repair the
wiring from lower ECAM DU (4WT2) to DMC2 (1WT2) from pins AA/38, 39 to pins AB/10D, 10E ASM 316104.
- replace the DMC-2 [1WT2] AMM 31-63-34-000-001 and AMM 31-63-34-400-001.
D. Do the test given in Para. 3.