W DOC AIRBUS | TSM A320F

Loss of the FCU 1 Output Buses by the DMC 2


TASK 31-63-00-810-995-A
Loss of the FCU 1 Output Buses by the DMC 2


1. Possible Causes
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
TSM TASK 31-63-81-810-931-A
Loss of the FCU 1 Channel A Output Bus by DMC 2
TSM TASK 31-63-81-810-932-A
Loss of the FCU 1 Channel B Output Bus by DMC 2
AMM 22-81-12-000-001
Removal of the FCU
AMM 22-81-12-400-001
Installation of the FCU
AMM 31-60-00-740-007
GROUND SCANNING Test of the DMC
3. Fault Confirmation
Subtask 31-63-00-740-390-A ** ON A/C NOT FOR ALL
A. Test
Do the Ground Scanning Test of the DMC AMM 31-60-00-740-007.
4. Fault Isolation
Subtask 31-63-00-810-248-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message FCU1(2CA)/DMC2(1WT2):
   (1) If the fault continues:
Subtask 31-63-00-740-391-A ** ON A/C NOT FOR ALL
B. Do the test given in Para. 3.A.
[Rev.8 from Aug 2018] 2026.04.04 04:30:52 UTC