Loss of the ADIRU 3 Data to the DMC
TASK 31-63-00-810-993-A
Loss of the ADIRU 3 Data to the DMC
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 31-63-00-740-386-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 31-63-00-810-246-A ** ON A/C NOT FOR ALL
Subtask 31-63-00-740-387-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:40:10 UTC
Loss of the ADIRU 3 Data to the DMC
1. Possible Causes
- ADIRU-3 [1FP3]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| TSM TASK 31-63-00-810-821-A | Loss of the ADC 3 Output Bus by the DMC 1 |
| TSM TASK 31-63-00-810-829-A | Loss of the ADC 3 Output Bus by the DMC 2 |
| TSM TASK 31-63-00-810-837-A | Loss of the ADC 3 Output Bus by the DMC 3 |
| AMM 31-60-00-740-007 | GROUND SCANNING Test of the DMC |
| AMM 34-12-34-000-001 | Removal of the ADIRU |
| AMM 34-12-34-400-001 | Installation of the ADIRU |
Subtask 31-63-00-740-386-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 31-63-00-810-246-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message ADIRU3(1FP3):
5. Close-up- Do the fault isolation (Para. 4. A.) of the following procedures (Ref. TSM TASK 31-63-00-810-821), (Ref. TSM TASK 31-63-00-810-829) and (Ref. TSM TASK 31-63-00-810-837).
- replace the ADIRU-3 [1FP3] AMM 34-12-34-000-001 and AMM 34-12-34-400-001
Subtask 31-63-00-740-387-A ** ON A/C NOT FOR ALL
A. Do the test given in Para. 3.A.