Loss of the Brightness Control on the SD DU
TASK 31-63-00-810-981-A
Loss of the Brightness Control on the SD DU
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 31-63-00-740-362-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 31-63-00-810-234-A ** ON A/C NOT FOR ALL
Subtask 31-63-00-740-363-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:30:51 UTC
Loss of the Brightness Control on the SD DU
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 31-60-00-740-004 | EIS System Test |
| AMM 31-61-12-000-001 | Removal of the ECAM Control Panel |
| AMM 31-61-12-400-001 | Installation of the ECAM Control Panel |
| AMM 31-63-22-000-001 | Removal of the Display Unit |
| AMM 31-63-22-400-001 | Installation of the Display Unit |
| ASM 316800 |
Subtask 31-63-00-740-362-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 31-63-00-810-234-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message DU SD(4WT2)/ECP(6WT):
5. Close-up- replace the DU-ECAM, LOWER [4WT2] , AMM 31-63-22-000-001 and AMM 31-63-22-400-001
- replace the CTL PNL-ECAM [6WT] , AMM 31-61-12-000-001 and AMM 31-61-12-400-001
- remove the SD DU (4WT2) and the ECAM CTL PNL (6WT) AMM 31-63-22-000-001
- check the wiring between the connector AA of the SD DU (4WT2) and the connector A of the ECAM CTL PNL (6WT) ASM 316800.
- install the SD DU and the ECAM CTL PNL AMM 31-63-22-400-001
Subtask 31-63-00-740-363-A ** ON A/C NOT FOR ALL
A. Do the test given in Para. 3.A.