Loss of the Brightness Control on the EWD DU
TASK 31-63-00-810-980-A
Loss of the Brightness Control on the EWD DU
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 31-63-00-740-360-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 31-63-00-810-233-A ** ON A/C NOT FOR ALL
Subtask 31-63-00-740-361-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:30:50 UTC
Loss of the Brightness Control on the EWD DU
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 31-60-00-740-004 | EIS System Test |
| AMM 31-61-12-000-001 | Removal of the ECAM Control Panel |
| AMM 31-61-12-400-001 | Installation of the ECAM Control Panel |
| AMM 31-63-22-000-001 | Removal of the Display Unit |
| AMM 31-63-22-400-001 | Installation of the Display Unit |
| ASM 316800 |
Subtask 31-63-00-740-360-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 31-63-00-810-233-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message DU EWD(4WT1)/ECP(6WT):
5. Close-up- replace the DU-ECAM, UPPER [4WT1] , AMM 31-63-22-000-001 and AMM 31-63-22-400-001
- replace the CTL PNL-ECAM [6WT] , AMM 31-61-12-000-001 and AMM 31-61-12-400-001
- remove the EWD DU (4WT1) and the ECAM CTL PNL (6WT) AMM 31-63-22-000-001
- check the wiring between the connector AA of the EWD DU (4WT1) and the connector B of the ECAM CTL PNL (6WT) ASM 316800.
- install the EWD DU and the ECAM CTL PNL AMM 31-63-22-400-001
Subtask 31-63-00-740-361-A ** ON A/C NOT FOR ALL
A. Do the test given in Para. 3.A.