W DOC AIRBUS | TSM A320F

Loss of the CAPT ND DU or no Variation of Luminosity on the CAPT ND DU


TASK 31-63-00-810-977-A
Loss of the CAPT ND DU or no Variation of Luminosity on the CAPT ND DU


1. Possible Causes
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 31-60-00-740-004
EIS System Test
AMM 31-63-22-000-001
Removal of the Display Unit
AMM 31-63-22-400-001
Installation of the Display Unit
AMM 31-63-34-000-001
Removal of the DMC
AMM 31-63-34-400-001
Installation of the DMC
ASM 316801
3. Fault Confirmation
Subtask 31-63-00-740-354-A ** ON A/C NOT FOR ALL
A. Test
Do the EIS system test AMM 31-60-00-740-004.
4. Fault Isolation
Subtask 31-63-00-810-230-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message DU ND CAPT(3WT1)/ND CAPT POT(8WT1):
   (1) If there is no CAPT ND image:
     (a) If the fault continues:
  • remove the panel 301VU
  • on the panel 301VU, do a continuity check between the pins M and U of the connector 2101VC-A
       1 If there is continuity:
  • replace the POT-ND, CAPT [8WT1] (Ref. IPC 31680801)
  • install the panel 301VU.
       2 If there is no continuity:
   (2) If there is no variation of luminosity on CAPT ND DU with the CAPT ND potentiometer (8WT1) on the brightness position:
5. Close-up
Subtask 31-63-00-740-355-A ** ON A/C NOT FOR ALL
A. Do the test given in Para. 3.A.
[Rev.8 from Aug 2018] 2026.04.04 04:30:50 UTC