Loss of the CAPT PFD DU or no Variation of Luminosity on the CAPT PFD DU
TASK 31-63-00-810-974-A
Loss of the CAPT PFD DU or no Variation of Luminosity on the CAPT PFD DU
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 31-63-00-740-352-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 31-63-00-810-229-A ** ON A/C NOT FOR ALL
Subtask 31-63-00-740-353-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:30:50 UTC
Loss of the CAPT PFD DU or no Variation of Luminosity on the CAPT PFD DU
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 31-60-00-740-004 | EIS System Test |
| AMM 31-63-22-000-001 | Removal of the Display Unit |
| AMM 31-63-22-400-001 | Installation of the Display Unit |
| AMM 31-63-34-000-001 | Removal of the DMC |
| AMM 31-63-34-400-001 | Installation of the DMC |
| ASM 316801 |
Subtask 31-63-00-740-352-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 31-63-00-810-229-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message DU PFD CAPT(2WT1)/PFD CAPT POT(7WT1):
(1) If there is no CAPT PFD image:
5. Close-up(1) If there is no CAPT PFD image:
- on the panel 301VU, make sure that the CAPT PFD potentiometer (7WT1) is in the center position
- replace the PFD-CAPT [2WT1] , AMM 31-63-22-000-001 and AMM 31-63-22-400-001
- remove the panel 301VU
- on the panel 301VU, do a continuity check between the pins J and K of the connector 2101VC-A
- replace the POT-PFD, CAPT [7WT1] (Ref. IPC 31680801)
- install the panel 301VU.
- remove the DMC-1 [1WT1] ,
- remove the DMC-2 [1WT2]
- remove the DMC-3 [1WT3] AMM 31-63-34-000-001
- remove the PFD-CAPT [2WT1] AMM 31-63-22-000-001
- check the wiring between the related LRU and the first terminal block ASM 316801
- install the DMC-1 [1WT1] ,
- install the DMC-2 [1WT2]
- install the DMC-3 [1WT3] AMM 31-63-34-400-001
- install the PFD-CAPT [2WT1] AMM 31-63-22-400-001
- install the panel 301VU
- remove the PFD-CAPT [2WT1] AMM 31-63-22-000-001
- check the wiring between the CAPT PFD DU (2WT1) and the CAPT PFD potentiometer (7WT1) ASM 316801
- install the CAPT PFD DU (2WT1) AMM 31-63-22-400-001
Subtask 31-63-00-740-353-A ** ON A/C NOT FOR ALL
A. Do the test given in Para. 3.A.