W DOC AIRBUS | TSM A320F

EIS - Loss of the Red Gun


TASK 31-63-00-810-971-A
EIS - Loss of the Red Gun


1. Possible Causes
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 24-41-00-861-002
Energize the Aircraft Electrical Circuits from the External Power
AMM 24-41-00-862-002
De-energize the Aircraft Electrical Circuits Supplied from the External Power
AMM 31-60-00-860-001
EIS Start Procedure
AMM 31-60-00-860-002
EIS Stop Procedure
AMM 31-63-22-000-001
Removal of the Display Unit
AMM 31-63-22-400-001
Installation of the Display Unit
3. Fault Confirmation
Subtask 31-63-00-860-050-A ** ON A/C NOT FOR ALL
A. Do the operational test that follows:
   (1) Energize the aircraft electrical circuits
AMM 24-41-00-861-002
   (2) Do the EIS start procedure AMM 31-60-00-860-001.
   (3) Do a check of the colors displayed on the EIS Display Units.
4. Fault Isolation
Subtask 31-63-00-810-221-A ** ON A/C NOT FOR ALL
A. If the colors displayed on the upper ECAM display unit are not correct:
Subtask 31-63-00-810-222-A ** ON A/C NOT FOR ALL
B. If the colors displayed on the lower ECAM display unit are not correct:
Subtask 31-63-00-810-223-A ** ON A/C NOT FOR ALL
C. If the colors displayed on the CAPT ND are not correct:
Subtask 31-63-00-810-224-A ** ON A/C NOT FOR ALL
D. If the colors displayed on the F/O ND are not correct:
Subtask 31-63-00-810-225-A ** ON A/C NOT FOR ALL
E. If the colors displayed on the CAPT PFD are not correct:
Subtask 31-63-00-810-226-A ** ON A/C NOT FOR ALL
F. If the colors displayed on the F/O PFD are not correct:
5. Close-up
Subtask 31-63-00-860-051-A ** ON A/C NOT FOR ALL
A. Put the aircraft back to its initial configuration.
   (1) Do the EIS stop procedure
AMM 31-60-00-860-002.
   (2) De-energize the aircraft electrical circuits
AMM 24-41-00-862-002.
[Rev.8 from Aug 2018] 2026.04.04 04:30:50 UTC