W DOC AIRBUS | TSM A320F

Loss of the ARINC 429 Link from the FWC2 to the DMC3


TASK 31-63-00-810-966-A
Loss of the ARINC 429 Link from the FWC2 to the DMC3


1. Possible Causes
  • DMC-3 [1WT3]
  • wiring
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
ASM 315205
AMM 31-60-00-740-002
Perform Electronic Instrument System (EIS) Input Test
AMM 31-60-00-740-007
GROUND SCANNING Test of the DMC
AMM 31-63-34-000-001
Removal of the DMC
AMM 31-63-34-400-001
Installation of the DMC
3. Fault Confirmation
Subtask 31-63-00-865-195-A
A. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
121VUEIS/FWC2/SPLY2WWQ07
Subtask 31-63-00-740-342-A ** ON A/C NOT FOR ALL
B. Test
Do the EIS input test (system 3) AMM 31-60-00-740-002.
Subtask 31-63-00-740-342-B ** ON A/C NOT FOR ALL
B. Test
Do the Ground Scanning Test of the DMC AMM 31-60-00-740-007.
4. Fault Isolation
Subtask 31-63-00-810-214-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message:
DMC3: NO FWC2 DATA
   (1) If the fault continues:
  • do a check and repair the wiring from DMC3 (1WT3) pins AA/10J, 10K to the first terminal block ASM 315205.
Subtask 31-63-00-810-214-B ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message:
FWC2(1WW2) BUSX DATA/DMC3(1WT3)
   (1) If the fault continues:
  • do a check and repair the wiring from DMC3 (1WT3) pins AD/8C, 8D to the first terminal block ASM 315205.
Subtask 31-63-00-740-343-A
B. Do the test given in Para. 3.B.
[Rev.8 from Aug 2018] 2026.04.04 04:40:06 UTC