Loss of the ARINC 429 FWC2 Input of the DMC1
TASK 31-63-00-810-963-A
Loss of the ARINC 429 FWC2 Input of the DMC1
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 31-63-00-865-192-A
Subtask 31-63-00-810-211-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:30:50 UTC
Loss of the ARINC 429 FWC2 Input of the DMC1
1. Possible Causes
- DMC-1 [1WT1]
- wiring
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| ASM 315205 | |
| AMM 31-60-00-740-002 | Perform Electronic Instrument System (EIS) Input Test |
| AMM 31-60-00-740-007 | GROUND SCANNING Test of the DMC |
| AMM 31-63-34-000-001 | Removal of the DMC |
| AMM 31-63-34-400-001 | Installation of the DMC |
Subtask 31-63-00-865-192-A
A. Make sure that this(these) circuit breaker(s) is(are) closed:
Subtask 31-63-00-740-336-A ** ON A/C NOT FOR ALL Subtask 31-63-00-740-336-B ** ON A/C NOT FOR ALL 4. Fault Isolation| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 121VU | EIS/FWC2/SPLY | 2WW | Q07 |
Subtask 31-63-00-810-211-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message:
DMC1: NO FWC2 DATA
Subtask 31-63-00-810-211-B ** ON A/C NOT FOR ALL DMC1: NO FWC2 DATA
- replace the DMC-1 [1WT1] AMM 31-63-34-000-001 and AMM 31-63-34-400-001.
- do a check and repair the wiring from DMC1 (1WT1) pins AA/10J, 10K to the first terminal block ASM 315205.
A. If the test gives the maintenance message:
FWC2(1WW2) BUSX DATA/DMC1(1WT1)
Subtask 31-63-00-740-337-A FWC2(1WW2) BUSX DATA/DMC1(1WT1)
- replace the DMC-1 [1WT1] AMM 31-63-34-000-001 and AMM 31-63-34-400-001.
- do a check and repair the wiring from DMC1 (1WT1) pins AD/8C, 8D to the first terminal block ASM 315205.
B. Do the test given in Para. 3.B.