W DOC AIRBUS | TSM A320F

Loss of the FCU 2 Channel A Output Bus by the DMC 3


TASK 31-63-00-810-950-A
Loss of the FCU 2 Channel A Output Bus by the DMC 3


1. Possible Causes
  • DMC-3 [1WT3]
  • wiring
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 31-60-00-740-002
Perform Electronic Instrument System (EIS) Input Test
AMM 31-60-00-740-007
GROUND SCANNING Test of the DMC
ASM 316201
AMM 31-63-34-000-001
Removal of the DMC
AMM 31-63-34-400-001
Installation of the DMC
3. Fault Confirmation
Subtask 31-63-00-865-182-A
A. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
121VUAUTO FLT/FCU/29CA2M21
Subtask 31-63-00-740-310-A ** ON A/C NOT FOR ALL
B. Test
Do the EIS input test AMM 31-60-00-740-002.
Subtask 31-63-00-740-310-B ** ON A/C NOT FOR ALL
B. Test
Do the Ground Scanning Test of the DMC AMM 31-60-00-740-007.
4. Fault Isolation
Subtask 31-63-00-810-198-B ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message DMC 3 : NO FCU 2A DATA:
   (1) If the fault continues:
  • do a check and repair the wiring from the DMC 3 (1WT3) pins AA/1F, 1G to the first terminal block ASM 316201.
Subtask 31-63-00-810-198-C ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message FCU2(2CA)BUS FCU2A/DMC3(1WT3):
   (1) If the fault continues:
  • do a check and repair the wiring from the DMC 3 (1WT3) pins AA/6J, 6K to the first terminal block ASM 316201.
Subtask 31-63-00-740-311-A
B. Do the test given in Para. 3.B.
[Rev.8 from Aug 2018] 2026.04.04 04:40:08 UTC