Loss of the FAC 2 Output Bus by the DMC 3
TASK 31-63-00-810-945-A
Loss of the FAC 2 Output Bus by the DMC 3
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 31-63-00-865-177-A
Subtask 31-63-00-810-193-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:30:48 UTC
Loss of the FAC 2 Output Bus by the DMC 3
1. Possible Causes
- DMC-3 [1WT3]
- wiring
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| ASM 226501 | |
| AMM 31-60-00-740-002 | Perform Electronic Instrument System (EIS) Input Test |
| AMM 31-60-00-740-007 | GROUND SCANNING Test of the DMC |
| ASM 316201 | |
| AMM 31-63-34-000-001 | Removal of the DMC |
| AMM 31-63-34-400-001 | Installation of the DMC |
Subtask 31-63-00-865-177-A
A. Make sure that this(these) circuit breaker(s) is(are) closed:
Subtask 31-63-00-740-300-A ** ON A/C NOT FOR ALL Subtask 31-63-00-740-300-B ** ON A/C NOT FOR ALL 4. Fault Isolation| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 121VU | AUTO FLT/FAC2/28VDC | 5CC2 | M19 |
| 121VU | AUTO FLT/FAC2/26VAC | 14CC2 | M18 |
Subtask 31-63-00-810-193-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message DMC 3 : NO FAC 2 DATA:
Subtask 31-63-00-810-193-B ** ON A/C NOT FOR ALL - replace the DMC-3 [1WT3] AMM 31-63-34-000-001 and AMM 31-63-34-400-001.
- do a check and repair the wiring from the DMC 3 (1WT3) pins AA/3G, 3H to the first terminal block ASM 316201.
- do a check and repair the wiring from the DMC 3 (1WT3) pin AB/2K to the first terminal block ASM 226501.
A. If the test gives the maintenance message FAC2(1CC2)/DMC3(1WT3):
Subtask 31-63-00-740-301-A - replace the DMC-3 [1WT3] AMM 31-63-34-000-001 and AMM 31-63-34-400-001.
- do a check and repair the wiring from the DMC 3 (1WT3) pins AA/4J, 4K to the first terminal block ASM 316201.
- do a check and repair the wiring from the DMC 3 (1WT3) pin AB/5H to the first terminal block ASM 226501.
B. Do the test given in Para. 3.B.