Loss of the FQI 1 Output Bus by the DMC 2
TASK 31-63-00-810-938-A
Loss of the FQI 1 Output Bus by the DMC 2
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 31-63-00-865-170-A
Subtask 31-63-00-810-186-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:30:47 UTC
Loss of the FQI 1 Output Bus by the DMC 2
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 28-42-00-740-007 | Interrogation of the (SMITHS INDUSTRIES) FQIS Trouble Shooting Data |
| AMM 28-42-34-000-001 | Removal of the Fuel Quantity-Indicating Computer (FQIC) |
| AMM 28-42-34-400-001 | Installation of the Fuel Quantity-Indicating Computer (FQIC) |
| AMM 31-60-00-740-002 | Perform Electronic Instrument System (EIS) Input Test |
| AMM 31-60-00-740-007 | GROUND SCANNING Test of the DMC |
| ASM 316201 | |
| AMM 31-63-34-000-001 | Removal of the DMC |
| AMM 31-63-34-400-001 | Installation of the DMC |
Subtask 31-63-00-865-170-A
A. Make sure that this(these) circuit breaker(s) is(are) closed:
Subtask 31-63-00-740-286-A ** ON A/C NOT FOR ALL Subtask 31-63-00-740-286-B ** ON A/C NOT FOR ALL 4. Fault Isolation| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 49VU | FUEL/FQI/CHAN/1 | 1QT | A13 |
| 121VU | FUEL/FQI/CHANNEL/1 AND 2 | 8QT | L26 |
| 121VU | FUEL/FQI/CHAN/2 | 2QT | M27 |
Subtask 31-63-00-810-186-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message DMC 2 : NO FQI 1 DATA:
Subtask 31-63-00-810-186-B ** ON A/C NOT FOR ALL - replace FQIC [3QT] AMM 28-42-34-000-001 and AMM 28-42-34-400-001.
- replace the DMC-2 [1WT2] AMM 31-63-34-000-001 and AMM 31-63-34-400-001.
- do a check and repair the wiring from the DMC 2 (1WT2) pins AA/11A, 11B to the first terminal block ASM 316201.
A. If the test gives the maintenance message FQI(3QT)BUS1/DMC2(1WT2):
Subtask 31-63-00-740-287-A - replace FQIC [3QT] AMM 28-42-34-000-001 and AMM 28-42-34-400-001.
- replace the DMC-2 [1WT2] AMM 31-63-34-000-001 and AMM 31-63-34-400-001.
- Do the interrogation of the (SMITHS INDUSTRIES) FQIS Trouble Shooting Data AMM 28-42-00-740-007.
- do a check and repair the wiring from the DMC 2 (1WT2) pins AD/9J, 9K to the first terminal block ASM 316201.
B. Do the test given in Para. 3.B.