Loss of the input bus from the SDAC 2 to the DMC 3
TASK 31-63-00-810-931-A
Loss of the input bus from the SDAC 2 to the DMC 3
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 31-63-00-865-163-A
Subtask 31-63-00-810-179-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:30:47 UTC
Loss of the input bus from the SDAC 2 to the DMC 3
1. Possible Causes
- DMC-3 [1WT3]
wiring from the SDAC2 (1WV2) to the DMC3 (1WT3)
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| ASM 315404 | |
| AMM 31-60-00-740-002 | Perform Electronic Instrument System (EIS) Input Test |
| AMM 31-60-00-740-007 | GROUND SCANNING Test of the DMC |
| AMM 31-63-34-000-001 | Removal of the DMC |
| AMM 31-63-34-400-001 | Installation of the DMC |
Subtask 31-63-00-865-163-A
A. Make sure that this(these) circuit breaker(s) is(are) closed:
Subtask 31-63-00-740-272-A ** ON A/C NOT FOR ALL Subtask 31-63-00-740-272-B ** ON A/C NOT FOR ALL 4. Fault Isolation| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 121VU | EIS/SDAC/2/SPLY | 2WV | Q06 |
Subtask 31-63-00-810-179-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message:
DMC3 : NO SDAC2 DATA
Subtask 31-63-00-810-179-B ** ON A/C NOT FOR ALL DMC3 : NO SDAC2 DATA
- replace the DMC-3 [1WT3] , AMM 31-63-34-000-001 and AMM 31-63-34-400-001.
- do a check and repair the
wiring from the SDAC2 (1WV2) to the DMC3 (1WT3) , ASM 315404.
A. If the test gives the maintenance message:
SDAC2(1WV2)/DMC3(1WT3)
Subtask 31-63-00-740-273-A SDAC2(1WV2)/DMC3(1WT3)
- replace the DMC-3 [1WT3] , AMM 31-63-34-000-001 and AMM 31-63-34-400-001.
- do a check and repair the
wiring from the SDAC2 (1WV2) to the DMC3 (1WT3) , ASM 315404.
B. Do the test given in Para. 3.B.