Loss of the LGCIU 1 Output Bus by the DMC 3


TASK 31-63-00-810-922-A
Loss of the LGCIU 1 Output Bus by the DMC 3


1. Possible Causes
  • DMC-3 [1WT3]
  • wiring
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 31-60-00-740-002
Perform Electronic Instrument System (EIS) Input Test
AMM 31-60-00-740-007
GROUND SCANNING Test of the DMC
ASM 316201
AMM 31-63-34-000-001
Removal of the DMC
AMM 31-63-34-400-001
Installation of the DMC
3. Fault Confirmation
Subtask 31-63-00-865-154-A
A. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
49VUL/G/LGCIU/SYS1/NORM1GAC09
121VUHYDRAULIC/LGCIU/SYS1/GRND SPLY52GAQ34
Subtask 31-63-00-740-254-A ** ON A/C NOT FOR ALL
B. Test
Do the EIS input test AMM 31-60-00-740-002.
Subtask 31-63-00-740-254-B ** ON A/C NOT FOR ALL
B. Test
Do the Ground Scanning Test of the DMC AMM 31-60-00-740-007.
4. Fault Isolation
Subtask 31-63-00-810-170-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message DMC 3 : NO LGCIU 1 DATA:
   (1) If the fault continues:
  • do a check and repair the wiring from the DMC 3 (1WT3) pins AA/14D, 14E to the first terminal block ASM 316201.
Subtask 31-63-00-810-170-B ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message LGCIU1(5GA1)/DMC3(1WT3):
   (1) If the fault continues:
  • do a check and repair the wiring from the DMC 3 (1WT3) pins AD/7J, 7K to the first terminal block ASM 316201.
Subtask 31-63-00-740-255-A
B. Do the test given in Para. 3.B.