W DOC AIRBUS | TSM A320F

Loss of the FCU 1 Channel B Output Bus by the DMC 1


TASK 31-63-00-810-906-A
Loss of the FCU 1 Channel B Output Bus by the DMC 1


1. Possible Causes
  • DMC-1 [1WT1]
  • wiring
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 31-60-00-740-002
Perform Electronic Instrument System (EIS) Input Test
AMM 31-60-00-740-007
GROUND SCANNING Test of the DMC
ASM 316201
AMM 31-63-34-000-001
Removal of the DMC
AMM 31-63-34-400-001
Installation of the DMC
3. Fault Confirmation
Subtask 31-63-00-865-138-A
A. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
49VUAUTO FLT/FCU/19CA1B05
Subtask 31-63-00-740-222-A ** ON A/C NOT FOR ALL
B. Test
Do the EIS input test AMM 31-60-00-740-002.
Subtask 31-63-00-740-222-B ** ON A/C NOT FOR ALL
B. Test
Do the Ground Scanning Test of the DMC AMM 31-60-00-740-007.
4. Fault Isolation
Subtask 31-63-00-810-154-B ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message DMC 1 : NO FCU 1B DATA:
   (1) If the fault continues:
  • do a check and repair the wiring from the DMC 1 (1WT1) pins AA/2D, 2E to the first terminal block ASM 316201.
Subtask 31-63-00-810-154-C ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message FCU1(2CA)BUS FCU1B/DMC1(1WT1):
   (1) If the fault continues:
  • do a check and repair the wiring from the DMC 1 (1WT1) pins AA/1C, 1D to the first terminal block ASM 316201.
Subtask 31-63-00-740-223-A
B. Do the test given in Para. 3.B.
[Rev.8 from Aug 2018] 2026.04.04 04:30:45 UTC