Loss of the IRS 1 Output Bus by the DMC 3
TASK 31-63-00-810-863-A
Loss of the IRS 1 Output Bus by the DMC 3
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 31-63-00-865-095-A
Subtask 31-63-00-810-111-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:30:42 UTC
Loss of the IRS 1 Output Bus by the DMC 3
1. Possible Causes
- DMC-3 [1WT3]
- wiring
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 31-60-00-740-002 | Perform Electronic Instrument System (EIS) Input Test |
| AMM 31-60-00-740-007 | GROUND SCANNING Test of the DMC |
| ASM 316201 | |
| AMM 31-63-34-000-001 | Removal of the DMC |
| AMM 31-63-34-400-001 | Installation of the DMC |
| AMM 34-12-34-000-001 | Removal of the ADIRU |
| AMM 34-12-34-400-001 | Installation of the ADIRU |
Subtask 31-63-00-865-095-A
A. Make sure that this(these) circuit breaker(s) is(are) closed:
Subtask 31-63-00-740-136-A ** ON A/C NOT FOR ALL Subtask 31-63-00-740-136-B ** ON A/C NOT FOR ALL 4. Fault Isolation| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 49VU | NAV PROBES/ADIRU 1/AND AOA 1/26VAC | 5FP1 | F07 |
| 49VU | NAV PROBES/ADIRU1/115VAC | 4FP1 | F06 |
| 105VU | ADIRS/ADIRU1/28VDC | 6FP1 | C02 |
Subtask 31-63-00-810-111-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message DMC 3 : NO IRS 1 DATA:
Subtask 31-63-00-810-111-B ** ON A/C NOT FOR ALL - replace the DMC-3 [1WT3] AMM 31-63-34-000-001 and AMM 31-63-34-400-001.
- do a check and repair the wiring from the DMC 3 (1WT3) pins AA/5C, 5D to the first terminal block ASM 316201.
A. If the test gives the maintenance message ADIRU1(1FP1) BUS3 IR / DMC3(1WT3)
Subtask 31-63-00-740-137-A - replace the DMC-3 [1WT3] AMM 31-63-34-000-001 and AMM 31-63-34-400-001.
- do a check and repair the wiring from the ADIRU1 (1FP1) pins AB-10C/11C to the DMC3 (1WT3) pins AA-4C/4D ASM 316201.
- replace the ADIRU1 (1FP1) AMM 34-12-34-000-001 and AMM 34-12-34-400-001.
B. Do the test given in Para. 3.B.