W DOC AIRBUS | TSM A320F

Loss of the ADC 2 Output Bus by the DMC 3


TASK 31-63-00-810-844-A
Loss of the ADC 2 Output Bus by the DMC 3


1. Possible Causes
  • DMC-3 [1WT3]
  • wiring
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 31-60-00-740-002
Perform Electronic Instrument System (EIS) Input Test
AMM 31-60-00-740-007
GROUND SCANNING Test of the DMC
ASM 316201
AMM 31-63-34-000-001
Removal of the DMC
AMM 31-63-34-400-001
Installation of the DMC
AMM 34-12-34-000-001
Removal of the ADIRU
AMM 34-12-34-400-001
Installation of the ADIRU
3. Fault Confirmation
Subtask 31-63-00-865-076-A
A. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
121VUADIRS/ADIRU/2PWR/SHED10FPN10
** ON A/C ALL
121VUADIRS/ADIRU/2/26VAC AND AOA5FP2N08
121VUADIRS/ADIRU/2/115VAC4FP2N06
121VUADIRS/ADIRU/2/28VDC6FP2N04
** ON A/C NOT FOR ALL
121VUADIRS/2PWR/SHED &/AOA2 MON10FPN10
Subtask 31-63-00-740-098-A ** ON A/C NOT FOR ALL
B. Test
Do the EIS input test AMM 31-60-00-740-002.
Subtask 31-63-00-740-098-B ** ON A/C NOT FOR ALL
B. Test
Do the Ground Scanning Test of the DMC AMM 31-60-00-740-007.
4. Fault Isolation
Subtask 31-63-00-810-092-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message:
DMC 3: NO ADC 2 DATA
   (1) If the fault continues:
  • do a check and repair the wiring from the DMC 3 (1WT3) pins AA/6G, 6H to the first terminal block ASM 316201.
Subtask 31-63-00-810-092-B ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message:
ADIRU2(1FP2) BUS3 ADR/DMC3(1FP3)
   (1) If the fault continues:
  • do a check and repair the wiring from the ADIRU2 (1FP2) pins AA-7A/7B to the DMC3 (1WT3) pins AA/5G/5H ASM 316201.
   (2) If the fault continues:
Subtask 31-63-00-740-099-A
B. Do the test given in Para. 3.B.
[Rev.8 from Aug 2018] 2026.04.04 04:30:40 UTC