Loss of the ADF 2 Output Bus by the DMC 1
TASK 31-63-00-810-823-A
Loss of the ADF 2 Output Bus by the DMC 1
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 31-63-00-865-055-A ** ON A/C NOT FOR ALL
Subtask 31-63-00-810-071-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:30:37 UTC
Loss of the ADF 2 Output Bus by the DMC 1
1. Possible Causes
- DMC-1 [1WT1]
- wiring
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 31-60-00-740-002 | Perform Electronic Instrument System (EIS) Input Test |
| AMM 31-60-00-740-007 | GROUND SCANNING Test of the DMC |
| ASM 316201 | |
| AMM 31-63-34-000-001 | Removal of the DMC |
| AMM 31-63-34-400-001 | Installation of the DMC |
Subtask 31-63-00-865-055-A ** ON A/C NOT FOR ALL
A. Make sure that this(these) circuit breaker(s) is(are) closed:
Subtask 31-63-00-740-056-A ** ON A/C NOT FOR ALL Subtask 31-63-00-740-056-B ** ON A/C NOT FOR ALL 4. Fault Isolation| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 121VU | COM NAV/ADF/2 | 1RP2 | K02 |
Subtask 31-63-00-810-071-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message DMC 1 : NO ADF 2 DATA:
Subtask 31-63-00-810-071-B ** ON A/C NOT FOR ALL - replace the DMC-1 [1WT1] AMM 31-63-34-000-001 and AMM 31-63-34-400-001.
- do a check and repair the wiring from DMC 2 (1WT2) pins AA/8G, 8H to the first terminal block ASM 316201.
A. If the test gives the maintenance message ADF2(2RP2)/DMC1(1WT1)
Subtask 31-63-00-740-057-B ** ON A/C NOT FOR ALL - replace the DMC-1 [1WT1] AMM 31-63-34-000-001 and AMM 31-63-34-400-001.
- do a check and repair the wiring from DMC 2 (1WT2) pins AA/7J, 7K to the first terminal block ASM 316201.
B. Do the test given in Para. 3.B.