Loss of the High Speed Bus Output from the DMC 2 detected by the ECAM Control Panel
TASK 31-63-00-810-814-A
Loss of the High Speed Bus Output from the DMC 2 detected by the ECAM Control Panel
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 31-63-00-710-062-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 31-63-00-810-056-B ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:30:37 UTC
Loss of the High Speed Bus Output from the DMC 2 detected by the ECAM Control Panel
1. Possible Causes
- DMC-2 [1WT2]
- wiring
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 31-50-00-710-001 | Ground Scanning of the Central Warning System |
| ASM 316103 | |
| AMM 31-63-34-000-001 | Removal of the DMC |
| AMM 31-63-34-400-001 | Installation of the DMC |
Subtask 31-63-00-710-062-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 31-63-00-810-056-B ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message ECP : NO DATA FROM DMC2 OR 3:
Subtask 31-63-00-710-063-A ** ON A/C NOT FOR ALL - replace the DMC-2 [1WT2] AMM 31-63-34-000-001 and AMM 31-63-34-400-001.
- do a check and repair the wiring from DMC 2 (1WT2) pins AB/1E, 1F to the first terminal block ASM 316103.
B. Do the test given in Para. 3.