W DOC AIRBUS | TSM A320F

Loss of the High Speed Bus Output from the DMC 3 (DMC 2 Switched to DMC 3) Detected by the FWC 1


TASK 31-63-00-810-813-A
Loss of the High Speed Bus Output from the DMC 3 (DMC 2 Switched to DMC 3) Detected by the FWC 1


1. Possible Causes
  • DMC-3 [1WT3]
  • wiring
  • wiring between the DMC 3 (1WT3) and the DMC 2 (1WT2)
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 31-50-00-710-001
Ground Scanning of the Central Warning System
ASM 316103
AMM 31-63-34-000-001
Removal of the DMC
AMM 31-63-34-400-001
Installation of the DMC
ASM 316805
3. Fault Confirmation
Subtask 31-63-00-710-072-A
A. Test
Do the operational test of the central warning systems (FWC) AMM 31-50-00-710-001.
4. Fault Isolation
Subtask 31-63-00-810-061-B
A. If the test gives the maintenance message FWC1 : NO DATA FROM DMC2 OR 3:
   (1) If the fault continues:
  • do a check of the wiring from DMC 2 (1WT2) pins AB/1E, 1F to the first terminal block ASM 316103.
     (a) If there is no continuity:
  • repair the wiring.
     (b) If there is continuity:
  • do a check and repair the wiring between the DMC 3 (1WT3) and the DMC 2 (1WT2) from pins AB/1E, 1F to pins AA/13E, 13F ASM 316805.
Subtask 31-63-00-710-073-A ** ON A/C NOT FOR ALL
B. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:30:37 UTC