W DOC AIRBUS | TSM A320F

Loss of the input bus 2 by the ECAM control panel


TASK 31-61-00-810-809-A
Loss of the input bus 2 by the ECAM control panel


1. Possible Causes
  • CTL PNL-ECAM [6WT]
  • wiring
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 31-50-00-710-001
Ground Scanning of the Central Warning System
ASM 316103
AMM 31-61-12-000-001
Removal of the ECAM Control Panel
AMM 31-61-12-400-001
Installation of the ECAM Control Panel
3. Fault Confirmation
Subtask 31-61-00-865-051-A
A. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
49VUEIS/ECAM/CTL/PNL15WTE12
49VUEIS/DMC3/SWTG21WT3E07
121VUEIS/DMC3/SPLY10WT3Q09
121VUEIS/DMC2/SPLY10WT2Q08
121VUEIS/DMC2/SWTG21WT2R08
Subtask 31-61-00-710-060-A
B. Test
Do the operational test of the central warning systems (FWC) AMM 31-50-00-710-001.
4. Fault Isolation
Subtask 31-61-00-810-058-B
A. If the test gives the maintenance message ECP : NO DATA FROM DMC1 or 3
   (1) If the fault continues:
  • do a check and repair the wiring from ECAM control panel (6WT) pins B/K, L to the first terminal block ASM 316103.
Subtask 31-61-00-710-061-A
B. Do the test given in Para. 3.B.
[Rev.8 from Aug 2018] 2026.04.04 04:30:36 UTC