Loss of the input bus 1 by the ECAM control panel


TASK 31-61-00-810-808-A
Loss of the input bus 1 by the ECAM control panel


1. Possible Causes
  • CTL PNL-ECAM [6WT]
  • wiring
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 31-50-00-710-001
Ground Scanning of the Central Warning System
ASM 316103
AMM 31-61-12-000-001
Removal of the ECAM Control Panel
AMM 31-61-12-400-001
Installation of the ECAM Control Panel
3. Fault Confirmation
Subtask 31-61-00-865-050-A
A. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
49VUEIS/ECAM/CTL/PNL15WTE12
49VUEIS/DMC1/SPLY10WT1E11
49VUEIS/DMC1/SWTG21WT1E09
49VUEIS/DMC3/SWTG21WT3E07
121VUEIS/DMC3/SPLY10WT3Q09
Subtask 31-61-00-710-058-A
B. Test
Do the operational test of the central warning systems (FWC) AMM 31-50-00-710-001.
4. Fault Isolation
Subtask 31-61-00-810-057-B
A. If the test gives the maintenance message ECP : NO DATA FROM DMC1 or 3:
   (1) If the fault continues:
  • do a check and repair the wiring from ECAM control panel (6WT) pins B/G,H to the first terminal block ASM 316103.
Subtask 31-61-00-710-059-A
B. Do the test given in Para. 3.B.