Loss of the Output Bus 2 of the ECAM Control Panel
TASK 31-61-00-810-801-A
Loss of the Output Bus 2 of the ECAM Control Panel
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 31-61-00-710-050-A 4. Fault Isolation
Subtask 31-61-00-810-050-A
[Rev.8 from Aug 2018]
2026.04.04 04:30:36 UTC
Loss of the Output Bus 2 of the ECAM Control Panel
1. Possible Causes
- CTL PNL-ECAM [6WT]
- wiring
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 31-50-00-710-001 | Ground Scanning of the Central Warning System |
| ASM 316103 | |
| AMM 31-61-12-000-001 | Removal of the ECAM Control Panel |
| AMM 31-61-12-400-001 | Installation of the ECAM Control Panel |
Subtask 31-61-00-710-050-A 4. Fault Isolation
Subtask 31-61-00-810-050-A
A. If the test gives the maintenance message FWC 1 : NO DATA FROM ECP:
Subtask 31-61-00-710-051-A - replace the CTL PNL-ECAM [6WT] , AMM 31-61-12-000-001 and AMM 31-61-12-400-001.
- do a check and repair the wiring from the ECAM control panel (6WT) pins B/E, F to the first terminal block , ASM 316103.
B. Do the test given in Para. 3.