W DOC AIRBUS | TSM A320F

Loss of the PHC 1 Output Bus of the SDAC 2


TASK 31-54-00-810-974-A
Loss of the PHC 1 Output Bus of the SDAC 2


1. Possible Causes
  • SDAC-2 [1WV2]
  • wiring
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 31-50-00-710-001
Ground Scanning of the Central Warning System
ASM 315403
AMM 31-55-34-000-001
Removal of the SDAC
AMM 31-55-34-400-001
Installation of the SDAC
3. Fault Confirmation
Subtask 31-54-00-865-161-A ** ON A/C NOT FOR ALL
A. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUANTI ICE/PROBES/AOA/14DA1D04
49VUANTI ICE/PROBES/PHC/12DA1D03
49VUANTI ICE/PROBES/PITOT/13DA1D02
122VUANTI ICE/PROBES/1/STATIC5DA1Z13
122VUANTI ICE/PROBES/1/TAT1DA1Z12
Subtask 31-54-00-710-379-A ** ON A/C NOT FOR ALL
B. Test
Do the ground scanning of the central warning system AMM 31-50-00-710-001.
4. Fault Isolation
Subtask 31-54-00-810-224-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message SDAC2:NO DATA FROM PHC1:
   (1) If the fault continues:
  • do a check and repair the wiring from the SDAC 2 (1WV2) pins AE/07B, 07C to the first terminal block, ASM 315403.
Subtask 31-54-00-710-380-A ** ON A/C NOT FOR ALL
B. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:30:35 UTC