Loss of the CIDS2 Bus of the SDAC 1
TASK 31-54-00-810-967-A
Loss of the CIDS2 Bus of the SDAC 1
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 31-54-00-865-154-A
Subtask 31-54-00-810-217-A
[Rev.8 from Aug 2018]
2026.04.04 04:30:35 UTC
Loss of the CIDS2 Bus of the SDAC 1
1. Possible Causes
- SDAC-1 [1WV1]
- wiring
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| ASM 237302 | |
| AWM 237310 | |
| AMM 31-50-00-710-001 | Ground Scanning of the Central Warning System |
| AMM 31-55-34-000-001 | Removal of the SDAC |
| AMM 31-55-34-400-001 | Installation of the SDAC |
Subtask 31-54-00-865-154-A
A. Make sure that this(these) circuit breaker(s) is(are) closed:
Subtask 31-54-00-710-365-A 4. Fault Isolation| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 49VU | COM/CIDS/DIR ESS/2 | 157RH | G02 |
| ** ON A/C NOT FOR ALL | |||
| 49VU | COM DIR ESS/2 | 157RH | G02 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | COM/CIDS/DIR 2/BAT | 146RH | P14 |
| 121VU | COM/CIDS/BAT/CTL | 148RH | P12 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | COM NAV/CIDS/DIR NORM/2 | 156RH | M06 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | COM NAV/CIDS/DIR NORM/2 | 156RH | M07 |
Subtask 31-54-00-810-217-A
A. If the test gives the maintenance message
SDAC1:NO DATA FROM CIDS2:
Subtask 31-54-00-710-366-A SDAC1:NO DATA FROM CIDS2:
- replace the SDAC-1 [1WV1] , AMM 31-55-34-000-001 and AMM 31-55-34-400-001.
- do a check and repair the wiring from the SDAC 1 (1WV1) pins AB/08G, 08H to the first terminal block, AWM 237310 and ASM 237302.
B. Do the test given in Para. 3.