W DOC AIRBUS | TSM A320F

Loss of the YELLOW RSVR TEMP Input of the SDAC 1 and SDAC 2


TASK 31-54-00-810-960-A
Loss of the YELLOW RSVR TEMP Input of the SDAC 1 and SDAC 2


1. Possible Causes
  • TEMP TRANSM SWITCH [3381GR]
  • wiring
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 29-33-11-000-003
Removal of the Temperature Transmitter
AMM 29-33-11-400-003
Installation of the Temperature Transmitter
AMM 31-50-00-710-001
Ground Scanning of the Central Warning System
AWM 315411
3. Fault Confirmation
Subtask 31-54-00-710-351-A
A. Test
Do the ground scanning of the Central Warning System AMM 31-50-00-710-001.
4. Fault Isolation
Subtask 31-54-00-810-209-A
A. If the test gives the maintenance messages SDAC1 : Y HYD TEMP XMTR 3381GR and SDAC2 : Y HYD TEMP XMTR 3381GR:
   (1) If the fault continues:
  • do a check and repair the wiring :
    . from the Temperature Transmitter (3381GR) pins A/E, D to the SDAC1 (1WV1) pins AE/12J, 12K AWM 315411.
    . from the Temperature Transmitter (3381GR) pins A/K, J to the SDAC2 (1WV2) pins AE/12J, 12K AWM 315411.
Subtask 31-54-00-710-352-A
B. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:30:34 UTC