Unwanted Display of the CABIN READY Memo
TASK 31-54-00-810-952-A
Unwanted Display of the CABIN READY Memo
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 31-54-00-740-062-A
Subtask 31-54-00-810-200-A
[Rev.8 from Aug 2018]
2026.04.04 04:30:34 UTC
Unwanted Display of the CABIN READY Memo
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 31-55-34-000-001 | Removal of the SDAC |
| AMM 31-55-34-400-001 | Installation of the SDAC |
Subtask 31-54-00-740-062-A
A. Not applicable, the fault is evident.
4. Fault IsolationSubtask 31-54-00-810-200-A
A. If the fault symptom is identified by the crew observation:
Unwanted display of CABIN READY memo
(1) Do a check for a ground signal at the SDAC1 (1WV1) and SDAC2 (1WV2) connectors:
1 Replace the SDAC-1 [1WV1] AMM 31-55-34-000-001 and AMM 31-55-34-400-001.
2 If the fault continues:
Subtask 31-54-00-740-063-A Unwanted display of CABIN READY memo
(1) Do a check for a ground signal at the SDAC1 (1WV1) and SDAC2 (1WV2) connectors:
- pin AA/5G
- pin AD/5C
- repair as necessary.
1 Replace the SDAC-1 [1WV1] AMM 31-55-34-000-001 and AMM 31-55-34-400-001.
2 If the fault continues:
- replace the SDAC-2 [1WV2] AMM 31-55-34-000-001 and AMM 31-55-34-400-001.
B. Make sure that the CABIN READY right memo is not shown.