W DOC AIRBUS | TSM A320F

Loss of the GAPCU Bus of the SDAC2


TASK 31-54-00-810-951-A
Loss of the GAPCU Bus of the SDAC2


1. Possible Causes
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 24-41-34-000-001
Removal of the Ground Power Control Unit (GPCU)
AMM 24-41-34-400-001
Installation of the Ground Power Control Unit (GPCU)
AMM 31-50-00-710-001
Ground Scanning of the Central Warning System
ASM 315403
AMM 31-55-34-000-001
Removal of the SDAC
AMM 31-55-34-400-001
Installation of the SDAC
3. Fault Confirmation
Subtask 31-54-00-710-333-A
A. Do the ground scanning of the central warning system AMM 31-50-00-710-001.
4. Fault Isolation
Subtask 31-54-00-810-199-A
A. If the test gives the maintenance message:

SDAC2: NO DATA FROM GAPCU
   (1) Replace the SDAC-2 [1WV2] AMM 31-55-34-000-001 and AMM 31-55-34-400-001.
   (2) If the fault continues:

   (3) If the fault continues:

do a check and repair the wiring between the GAPCU (24XG) to the SDAC2 (1WV2) ASM 315403.
     (a) GAPCU (24XG) connector AA/8F, 7F to the SDAC2 (1WV2) connector AB/10J, 10K.
     (b) GAPCU (24XG) connector AA/8F, 7F to the SDAC2 (1WV2) connector AE/10A, 10B.
Subtask 31-54-00-710-334-A
B. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:30:34 UTC