Loss of the GCU1 Bus of the SDAC2
TASK 31-54-00-810-947-A
Loss of the GCU1 Bus of the SDAC2
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
3. Fault Confirmation
Subtask 31-54-00-710-325-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 31-54-00-810-195-A ** ON A/C NOT FOR ALL
[Rev.8 from Aug 2018]
2026.04.04 04:30:34 UTC
Loss of the GCU1 Bus of the SDAC2
1. Possible Causes
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 24-22-34-000-001 | Removal of the GCU-1(2) |
| AMM 24-22-34-400-001 | Installation of the GCU-1(2) |
| AMM 31-50-00-710-001 | Ground Scanning of the Central Warning System |
| AMM 31-55-34-000-001 | Removal of the SDAC |
| AMM 31-55-34-400-001 | Installation of the SDAC |
Subtask 31-54-00-710-325-A ** ON A/C NOT FOR ALL 4. Fault Isolation
Subtask 31-54-00-810-195-A ** ON A/C NOT FOR ALL
A. If the test gives the maintenance message:
SDAC2: NO DATA FROM GCU1
(1) Replace the SDAC-2 [1WV2] AMM 31-55-34-000-001 and AMM 31-55-34-400-001.
(2) If the fault continues:
Subtask 31-54-00-710-326-A ** ON A/C NOT FOR ALL SDAC2: NO DATA FROM GCU1
(1) Replace the SDAC-2 [1WV2] AMM 31-55-34-000-001 and AMM 31-55-34-400-001.
(2) If the fault continues:
- replace the GCU-1 [1XU1] AMM 24-22-34-000-001 and AMM 24-22-34-400-001.
- do a check and repair the wiring between the GCU1 (1XU1) and the SDAC2 (1WV2).
B. Do the test given in Para. 3.