Failure of the SDAC1
TASK 31-54-00-810-945-A
Failure of the SDAC1
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 31-54-00-710-321-A 4. Fault Isolation
Subtask 31-54-00-810-193-A
[Rev.8 from Aug 2018]
2026.04.04 04:30:33 UTC
Failure of the SDAC1
1. Possible Causes
- SDAC-1 [1WV1]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 31-50-00-710-001 | Ground Scanning of the Central Warning System |
| AMM 31-55-34-000-001 | Removal of the SDAC |
| AMM 31-55-34-400-001 | Installation of the SDAC |
Subtask 31-54-00-710-321-A 4. Fault Isolation
Subtask 31-54-00-810-193-A
A. If the test gives the maintenance messages
FWC1: NO DATA FROM SDAC1 and FWC2: NO DATA FROM SDAC1.
Subtask 31-54-00-710-322-A FWC1: NO DATA FROM SDAC1 and FWC2: NO DATA FROM SDAC1.
- replace the SDAC-1 [1WV1] AMM 31-55-34-000-001 and AMM 31-55-34-400-001.
B. Do the test given in Para. 3.