Failure of the SDAC2
TASK 31-54-00-810-944-A
Failure of the SDAC2
1. Possible Causes
A. Referenced Information
3. Fault Confirmation
Subtask 31-54-00-710-343-A 4. Fault Isolation
Subtask 31-54-00-810-205-A
[Rev.8 from Aug 2018]
2026.04.04 04:30:33 UTC
Failure of the SDAC2
1. Possible Causes
- SDAC-2 [1WV2]
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| AMM 31-50-00-710-001 | Ground Scanning of the Central Warning System |
| AMM 31-55-34-000-001 | Removal of the SDAC |
| AMM 31-55-34-400-001 | Installation of the SDAC |
Subtask 31-54-00-710-343-A 4. Fault Isolation
Subtask 31-54-00-810-205-A
A. If the test gives the maintenance messages:
FWC1: NO DATA FROM SDAC2 and FWC2: NO DATA FROM SDAC2
Subtask 31-54-00-710-344-A FWC1: NO DATA FROM SDAC2 and FWC2: NO DATA FROM SDAC2
- replace the SDAC-2 [1WV2] AMM 31-55-34-000-001 and AMM 31-55-34-400-001.
B. Do the test given in Para. 3.