W DOC AIRBUS | TSM A320F

Loss of the BMC 1 and BMC 2 Buses of the SDAC 2


TASK 31-54-00-810-943-A
Loss of the BMC 1 and BMC 2 Buses of the SDAC 2


1. Possible Causes
  • SDAC-2 [1WV2]
  • wiring
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 31-50-00-710-001
Ground Scanning of the Central Warning System
ASM 315403
AMM 31-55-34-000-001
Removal of the SDAC
AMM 31-55-34-400-001
Installation of the SDAC
3. Fault Confirmation
Subtask 31-54-00-865-140-A
A. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUAIR BLEED/ENG 1/CTL3HA1D12
49VUAIR BLEED/ENG 1/MONG2HA1D11
** ON A/C NOT FOR ALL
49VUAIR BLEED/ENG 2/MONG3HA2D12
49VUAIR BLEED/ENG 1/CTL2HA1D11
** ON A/C NOT FOR ALL
122VUAIR BLEED/ENG 2/CTL3HA2Z23
122VUAIR BLEED/ENG 2/MONG2HA2Z22
** ON A/C NOT FOR ALL
122VUAIR BLEED/ENG 1/MONG3HA1Z23
122VUAIR BLEED/ENG 2/CTL2HA2Z22
Subtask 31-54-00-710-319-A
B. Test
Do the ground scanning of the central warning systems AMM 31-50-00-710-001.
4. Fault Isolation
Subtask 31-54-00-810-192-A
A. If the test gives the maintenance message SDAC 2 : NO DATA FROM BMC 1+2:
   (1) If the fault continues:
  • do a check and repair as necessary the wiring from the SDAC 2 (1WV2)
    . pins AB/12G, 12H to the first terminal block
    . pins AE/12C, 12D to the first terminal block ASM 315403.
Subtask 31-54-00-710-320-A
B. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:30:33 UTC