W DOC AIRBUS | TSM A320F

Loss of the SFCC 1 and SFCC 2 Buses of the SDAC 2


TASK 31-54-00-810-939-A
Loss of the SFCC 1 and SFCC 2 Buses of the SDAC 2


1. Possible Causes
  • SDAC-2 [1WV2]
  • wiring
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 31-50-00-710-001
Ground Scanning of the Central Warning System
ASM 315403
AMM 31-55-34-000-001
Removal of the SDAC
AMM 31-55-34-400-001
Installation of the SDAC
3. Fault Confirmation
Subtask 31-54-00-865-136-A
A. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
49VUFLIGHT CONTROLS/SLT FLP/POS/IND 11CNB12
49VUFLIGHT CONTROLS/FLP/CTL AND MONG/SYS16CVB07
49VUFLIGHT CONTROLS/SLT/CTL AND MONG/SYS15CVB06
121VUFLIGHT CONTROLS/WTB/FLP/SYS212CVP20
121VUFLIGHT CONTROLS/WTB/SLT/SYS211CVP19
121VUFLIGHT CONTROLS/SLT FLP/2POS/IND2CNP16
121VUFLIGHT CONTROLS/FLP/CTL AND/MONG/SYS28CVQ21
121VUFLIGHT CONTROLS/SLT/CTL/SYS27CVR21
122VUFLIGHT CONTROLS/WTB/FLP/SYS110CVS07
122VUFLIGHT CONTROLS/WTB/SLT/SYS19CVS06
Subtask 31-54-00-710-311-A
B. Test
Do the ground scanning of the central warning systems AMM 31-50-00-710-001.
4. Fault Isolation
Subtask 31-54-00-810-188-A
A. If the test gives the maintenance message SDAC 2 : NO DATA FROM SFCC 1+2:
   (1) If the fault continues:
  • do a check and repair as necessary the wiring from the SDAC 2 (1WV2)
    . pins AB/11J, 11K to the first terminal block
    . pins AE/11A, 11B to the first terminal block ASM 315403.
Subtask 31-54-00-710-312-A
B. Do the test given in Para. 3.
[Rev.8 from Aug 2018] 2026.04.04 04:30:33 UTC