Loss of the Output Buses 1+2 of the Zone Temperature Controller by the SDAC 1


TASK 31-54-00-810-936-A
Loss of the Output Buses 1+2 of the Zone Temperature Controller by the SDAC 1


1. Possible Causes
  • SDAC-1 [1WV1]
  • wiring
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
AMM 31-50-00-710-001
Ground Scanning of the Central Warning System
ASM 315403
AMM 31-55-34-000-001
Removal of the SDAC
AMM 31-55-34-400-001
Installation of the SDAC
3. Fault Confirmation
Subtask 31-54-00-865-133-A
A. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
122VUAIR COND/ZONE TEMP CTL/28VDC/SYS24HKV20
122VUAIR COND/ZONE TEMP CTL/28VDC/SYS13HKV19
122VUAIR COND/ZONE TEMP CTL/115VAC/SYS22HKV18
122VUAIR COND/ZONE TEMP CTL/115VAC/SYS11HKV17
Subtask 31-54-00-710-305-A
B. Test
Do the ground scanning of the central warning systems AMM 31-50-00-710-001.
4. Fault Isolation
Subtask 31-54-00-810-185-A
A. If the test gives the maintenance message SDAC 1 : NO DATA FROM ECS 1+2:
   (1) If the fault continues:
  • do a check and repair as necessary the wiring from the SDAC 1 (1WV1)
    . pins AB/14J, 14K to the first terminal block
    . pins AE/14A, 14B to the first terminal block ASM 315403.
Subtask 31-54-00-710-306-A
B. Do the test given in Para. 3.